ADSS Kevlar Armored Double Sheath Optical Cable

ADSS Kevlar yarn Armored fiber optic cable with double jacketsDescriptionADSS (All-Dielectric Self-Supporting) cable is ideal for installation in distribution as well as transmission environments, even when live-line installations are&

Featured Products


ADSS Kevlar yarn Armored fiber optic cable with double jackets

Description

ADSS (All-Dielectric Self-Supporting) cable is ideal for installation in distribution as well as transmission 
environments, even when live-line installations are required. As it's name indicates, there is no support or 
messenger wire required, so installation is achieved in a single pass, making ADSS an economical and simpemeans of achieving a fber optic network. EFON manufactures its own line of attachment hardware as well as supplies formed wire fittings when preferred.


 
ADSS Kevlar Yarn Armored Fiber Optic Cable with Double Jackets

Product Construction:

Fiber:
2-288 fibers
Uni-loose tube gel-filled


Central Strength Member:
Fiberglass reinforced plastic (FRP)

Inner Jacket:
Black UV and waterproof polyethylene (PE).

Strength Member:
Dupon Kevlar YarnOuter Jacket:
Black UV and waterproof polyethylene (PE).


Features:

1.Can be installed without shutting off the power.
2.Excellent AT performance. The maximum inductive
3.at the operating point of AT jacket can reach 25kV.
4.Light weight and small diameter reducing the load
5.caused by ice and wind and the load on towers and backprops.
6.Large span lengths and the largest span is over 500m.
7.Good performance of tensile strength and temperature.
8.The design life span is over 30 years.



Applications:

The actual status of overhead power lines is taken into full consideration when ADSS cable is being designed.
For overhead power lines under 110kV, PE outer sheath is applied.
For power lines equal to or over 110kV, AT outer sheath is applie
d.


TEST ROOM
ADSS Kevlar Yarn Armored Fiber Optic Cable with Double Jackets

PACKAGE

ADSS Kevlar Yarn Armored Fiber Optic Cable with Double Jackets
 
Products Standard:

Mechanical Performance
Max Tension PerformanceIEC 60794-1-2-E
Max. Operation TensionIEC 60794-1-2-E1
Crush TestIEC 6079 -1-2-E3
Impact Test IEC 60794-1-2-E4
Repeated BendingIEC 60794-1-2-E6
Torsion TestIEC 60794-1-2-E7
Cable bend  IEC 60794-1-2-E11A
Attenuation CoefficientITU-T G.652
Structural Test IEC-60793-1-20
Environmental Performance
Temperature Cycling IEC 60794-1-2-F1
Water PenetrationIEC 60794-1-2-F5B
Filing Compound FlowIEC 60794-1-E14

Structrure and Technical Specifications
Fiber
Count
Nominal
Diameter
(mm)
Nominal
Weight
(kg/km)
Max Fiber
Per Tube
Max No. of
(Tubes+fillers)
Allowable Tensile Load
(N)
Allowable Crush Resistance
(N/100mm)
Short TermLong TermShort TermLong Term
2~3612.1125663000100030001000
38~7213.91351263000100030001000
74~9616.01701283000100030001000
98~12016.621012103000100030001000
122~14418.224512123000100030001000
146~21618.32501218(2ayers)3000100030001000
>144Available upon customer's request